網站導覽  
美國WPI產品
 
放大器與靜電計
 
刺激器與隔離器
 
動物生理學
 
生物傳感器
 
細胞與組織研究
 
數據採集系統
 
手術與顯微解剖工具
 
氣體麻醉機、電刀、燒灼儀
 
玻璃毛細管
 
顯微操作儀
 
顯微鏡與攝影器材
 
微鍛儀與拉針器
 
幫浦與顯微注射器材
 
實驗室耗材
 
 


  • Pressure or volume-cycled
  • Pressure cycling prevents hyperinflation of tiny animal lungs
  • External lung pressure monitoring in pressure-cycling mode
  • Wide tidal volume and rate range
  • Internal air pump

 

   Data Sheet

The Small Animal Ventilator, suitable for a mouse or guinea pig, operates as either a volume or pressure-cycled ventilator, meaning that it dispenses a designated volume of air with each breath or it ventilates until a designated lung pressure is reached. Pressure-cycled ventilation prevents hyper-inflation of small animal lungs. When the ventilator operates in Volume mode, it dispenses a known airflow into the lungs for a set inspiratory time to generate the desired tidal volumes. The three controls – respiratory rate, inspiratory time and flow rate – allow for accuracy and extraordinary flexibility over a wide range of volumes, breaths-per-minute and I/E ratios. When the ventilator operates in Pressure mode, a built-in solid-state transducer monitors airway pressure. Simply set the desired end-inspiratory pressure. During inspiration, airflow is introduced into the lungs until this pressure is reached, at which point inspiration is terminated. This mode is especially useful for tiny animals, where hyperinflation of the lungs is a danger. An output voltage corresponding to airway pressure is provided for external monitoring or recording.

The SAR-830/AP ventilator comes with an internal air pump, but it can also connect with an external pressurized air or gas source for operation. This can be any suitable breathing gas within the required pressure range or the output from an anesthesia machine. It is compatible with inhalation anesthetics and oxygen. This unit may be expanded to ventilate larger animals or multiple small animals simultaneously by adding external valve assemblies. A metered flow source is required for each external valve assembly. These valves are available for animals ranging in size from mice to large dogs.

Specification

Respiratory rate range 5-200 breaths/min
Tidal Volume range * 0.2 - 35ml
Inspiration time range 0-5.00 seconds
Inspiratory flow rate range 0-1000 ml/min
Pressure control range 0-50.0 cmH2O
Analog rate output voltage 10mV/breath/min
Analog pressure output voltage 50mV/cmH2O
Logic Sync Out voltage 5V (TTL)
Power requirements 120/240VAC, selectable
Input pressure range ** 3-20 psi
Dimensions 9Wx5.5Hx9D in(23x14x23 cm)

*Using internal valves. External valve assemblies available for larger animals.
** No pressure source required for model SAR


Citations

Ayata, C., Shin, H., & Dileköz, E. (2013). Hyperlipidemia disrupts cerebrovascular reflexes and worsens ischemic perfusion defect. Journal of Cerebral  …. Retrieved from http://www.nature.com/jcbfm/journal/v33/n6/abs/jcbfm201338a.html

Capone, C., Faraco, G., & Coleman, C. (2012). Endothelin 1–dependent neurovascular dysfunction in chronic intermittent hypoxia. …. Retrieved from http://hyper.ahajournals.org/content/60/1/106.short

Chen, C., Tsai, P., & Huang, C. (2013). Minocycline ameliorates lung and liver dysfunction in a rodent model of hemorrhagic shock/resuscitation plus abdominal compartment syndrome. Journal of Surgical Research. Retrieved from http://www.sciencedirect.com/science/article/pii/S0022480412003964

Constantin, S. (2013). In Vivo Recordings of GnRH Neuron Firing Reveal Heterogeneity and Dependence upon GABAA Receptor Signaling. The Journal of  …. Retrieved from http://www.jneurosci.org/content/33/22/9394.short

Duque, D., & Pérez-González, D. (2012). Topographic distribution, frequency, and intensity dependence of stimulus-specific adaptation in the inferior colliculus of the rat. The Journal of  …. Retrieved from http://www.jneurosci.org/content/32/49/17762.short

Erbayraktar, Z., & Gökmen, N. (2013). Experimental Traumatic Spinal Cord Injury. Tissue-Protective  …. Retrieved from http://link.springer.com/protocol/10.1007/978-1-62703-308-4_6

Faraco, G., Moraga, A., Moore, J., & Anrather, J. (2013). Circulating Endothelin-1 Alters Critical Mechanisms Regulating Cerebral Microcirculation. …. Retrieved from http://hyper.ahajournals.org/content/62/4/759.short

Hibert, P., & Prunier-Mirebeau, D. (2013). Apolipoprotein AI Is a Potential Mediator of Remote Ischemic Preconditioning. PloS one. Retrieved from http://dx.plos.org/10.1371/journal.pone.0077211

Hoffmann, U. (2012). Glucose modulation of spreading depression susceptibility. Journal of Cerebral  …. Retrieved from http://www.nature.com/jcbfm/journal/vaop/ncurrent/full/jcbfm2012132a.html

Hoffmann, U., & Sukhotinsky, I. (2012). Increased glucose availability does not restore prolonged spreading depression durations in hypotensive rats without brain injury. Experimental  …. Retrieved from http://www.sciencedirect.com/science/article/pii/S0014488612003226

Huang, C., Han, X., Li, X., & Lam, E. (2012). Critical role of connexin 43 in secondary expansion of traumatic spinal cord injury. The Journal of  …. Retrieved from http://www.jneurosci.org/content/32/10/3333.short

Jeanneteau, J., & Hibert, P. (2012). Microparticle release in remote ischemic conditioning mechanism. American Journal of …. Retrieved from http://ajpheart.physiology.org/content/303/7/H871.short

Kang, K., Coggins, M., Xiao, C., Rosenzweig, A., & Bischoff, J. (2013). Human vasculogenic cells form functional blood vessels and mitigate adverse remodeling after ischemia reperfusion injury in rats. Angiogenesis. Retrieved from http://link.springer.com/article/10.1007/s10456-013-9354-9

Lai, H., Younce, J., Albaugh, D., Kao, Y., & Shih, Y. (2014). Functional MRI reveals frequency-dependent responses during deep brain stimulation at the subthalamic nucleus or internal globus pallidus. NeuroImage. Retrieved from http://www.sciencedirect.com/science/article/pii/S1053811913008860

Looij, Y. Van De, & Mauconduit, F. (2012). Diffusion tensor imaging of diffuse axonal injury in a rat brain trauma model. NMR in  …. Retrieved from http://onlinelibrary.wiley.com/doi/10.1002/nbm.1721/full

Reznichenko, L., Cheng, Q., & Nizar, K. (2012). In vivo alterations in calcium buffering capacity in transgenic mouse model of synucleinopathy. The Journal of  …. Retrieved from http://vntin.com/www.jneurosci.org/content/32/29/9992.full

Shin, H., Huang, P., & Ayata, C. (2013). Rho-kinase inhibition improves ischemic perfusion deficit in hyperlipidemic mice. Journal of Cerebral Blood Flow &  …. Retrieved from http://www.nature.com/jcbfm/journal/vaop/ncurrent/full/jcbfm2013195a.html

Strohmaier, C., Reitsamer, H., & Kiel, J. (2013). Episcleral Venous Pressure and IOP Responses to Central Electrical Stimulation in the Rat. Investigative ophthalmology & visual …. Retrieved from http://www.iovs.org/content/54/10/6860.short

Tang, H., Lee, M., & Khuong, A. (2012). Diaphragm muscle atrophy in mouse following long-term mechanical ventilation. Muscle &  …. Retrieved from http://onlinelibrary.wiley.com/doi/10.1002/mus.23748/abstract

Zhang, Y., Yang, L., & Yang, Y. (2013). Low-dose taurine upregulates taurine transporter expression in acute myocardial ischemia. International  …. Retrieved from http://www.spandidos-publications.com/ijmm/31/4/817

 

 
 
 
關於太和實驗動物實驗儀器設備飼育管理儀器手術解剖器具美國WPI產品聯絡我們首頁