Features
When powered by +2 volts or more, LUME provides an output voltage signal proportional to incident light over the visible to near infra red spectrum. Containing a miniature silicon photodiode, the slender stainless steel probe can be easily mounted to do a wide variety of useful jobs, such as monitoring transmitted, reflected or interrupted light beams. Optic fibers up to 2 mm diameter may be inserted into the tip.
Extension Cord
An extension cord is available, however, it may diminish signal-to-noise ratio
Specifications
POSITIVE SUPPLY VOLTAGE |
+50 V, maximum |
NEGATIVE SUPPLY VOLTAGE |
-20 V, maximum |
LIGHT VOLTAGE |
50 mV minimum (per 5 mW/cm2 with 2870°K source) |
DARK OUTPUT VOLTAGE |
100 μV max. (+ 5 V supply) |
ANGULAR FIELD OF VIEW |
± 12 degrees off axis |
SPECTRAL RANGE |
400 - 1200 nm (peak at 860 nm) |
PROBE |
5 mm diam. x 100 mm, stainless steel |
|